Skip to calculator
⚙️
TorqueAndFeed TorqueAndFeed.com • B2B Reference

5/8"-18 UNF Grade 8 Torque & Tap Drill Spec

SAE J429 / ASTM A354 Grade BD

Live Joint Clamp & Torque Engine

K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
325.353 N·m
239.968 ft-lbs | 2879.61 in-lbs | 33.1767 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
102.473 kN
23,036.9 lbf
Target tension across joint interface
75% Tap Drill d - P
14.684 mm
37/64" (0.5781 in) (78% Eng.)
50% Hard Metal Drill: 15.11 mm
Direct Engineering Specification Summary

The recommended tightening torque for a 5/8"-18 UNF Grade 8 bolt is 325.353 N·m (239.968 ft-lbs) when dry (K=0.20) and 244.015 N·m (179.976 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 102.473 kN (23,036.9 lbf) at 75% proof load. Standard 75% tap drill is 37/64" (0.5781 in).

Thread & Hole Blueprint Visualizer

ASME B1.1 Unified Inch Screw Threads (60° UN)
d = 15.875 mm (0.625") P = 1.41111 mm 5/8"-18 UNF Close: 16.281mm Normal: 16.662mm Loose: 17.475mm
Stress Area (As) 165.133 mm²
Pitch Diameter (d2) 14.958 mm
Minor Diameter (d1) 14.347 mm

Step-by-Step Mathematical Derivation

VDI 2230 / ISO 898-1
Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (15.875 − 0.9382 × 1.41111)² = 165.133 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 165.133 mm² × 827.4 N/mm² = 136631 N (136.631 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 136631 N = 102473 N (102.473 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 15.875 mm × 102473 N) / 1000 = 325.353 N·m (239.968 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.

5/8"-18 UNF Torque Across All Grades & Friction Conditions

Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.

Nominal Size: 5/8"-18 UNF
Grade / Class Dry (K=0.20) Zinc (K=0.18) Oil (K=0.15) Moly (K=0.12) Clamp (kN) Proof (kN)
Grade 5 230.468 Nm
169.984 ft-lb
207.421 Nm
152.986 ft-lb
172.851 Nm
127.488 ft-lb
138.281 Nm
101.991 ft-lb
72.588 96.784
Grade 8 CURRENT 325.353 Nm
239.968 ft-lb
292.817 Nm
215.971 ft-lb
244.015 Nm
179.976 ft-lb
195.212 Nm
143.981 ft-lb
102.473 136.631
18-8 Stainless 122.017 Nm
89.995 ft-lb
109.815 Nm
80.996 ft-lb
91.513 Nm
67.496 ft-lb
73.21 Nm
53.997 ft-lb
38.431 51.241

Frequently Asked Engineering Questions (5/8"-18 UNF Grade 8)

What is the recommended tightening torque for a 5/8"-18 UNF Grade 8 bolt?
For a 5/8"-18 UNF SAE J429 Grade 8 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 325.353 N·m (239.968 ft-lbs / 2879.61 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 244.015 N·m (179.976 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 195.212 N·m (143.981 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping 5/8"-18 UNF internal threads?
The standard cut tap drill size for 5/8"-18 UNF is 37/64" (0.5781 in) (0.5781" / 14.684 mm), which delivers approximately 78% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 15.11 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a 5/8"-18 UNF Grade 8 fastener develop?
With a tensile stress area (As) of 165.133 mm² (0.25596 in²) and a nominal proof stress of 827.4 MPa (1,20,000 psi), a 5/8"-18 UNF Grade 8 fastener possesses an ultimate proof load of 136.631 kN (30,715.9 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 102.473 kN (23,036.9 lbf) across the joint interface.
What clearance hole diameters should be drilled for 5/8"-18 UNF bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a 5/8"-18 UNF fastener are: Close Fit = 16.281 mm (0.641"), Normal Fit = 16.662 mm (0.656"), and Loose Fit = 17.475 mm (0.688"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.