Skip to calculator
⚙️
TorqueAndFeed TorqueAndFeed.com • B2B Reference

1"-8 UNC Grade 5 Torque & Tap Drill Spec

SAE J429 / ASTM A449

Live Joint Clamp & Torque Engine

K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
872.677 N·m
643.653 ft-lbs | 7723.84 in-lbs | 88.9883 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
171.787 kN
38,619.2 lbf
Target tension across joint interface
75% Tap Drill d - P
22.225 mm
7/8" (0.8750 in) (92.4% Eng.)
50% Hard Metal Drill: 23.68 mm
Direct Engineering Specification Summary

The recommended tightening torque for a 1"-8 UNC Grade 5 bolt is 872.677 N·m (643.653 ft-lbs) when dry (K=0.20) and 654.508 N·m (482.74 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 171.787 kN (38,619.2 lbf) at 75% proof load. Standard 75% tap drill is 7/8" (0.8750 in).

Thread & Hole Blueprint Visualizer

ASME B1.1 Unified Inch Screw Threads (60° UN)
d = 25.4 mm (1") P = 3.175 mm 1"-8 UNC Close: 25.806mm Normal: 26.187mm Loose: 27mm
Stress Area (As) 390.802 mm²
Pitch Diameter (d2) 23.338 mm
Minor Diameter (d1) 21.963 mm

Step-by-Step Mathematical Derivation

VDI 2230 / ISO 898-1
Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (25.4 − 0.9382 × 3.175)² = 390.802 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 390.802 mm² × 586.1 N/mm² = 229049 N (229.049 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 229049 N = 171787 N (171.787 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 25.4 mm × 171787 N) / 1000 = 872.677 N·m (643.653 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.

1"-8 UNC Torque Across All Grades & Friction Conditions

Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.

Nominal Size: 1"-8 UNC
Grade / Class Dry (K=0.20) Zinc (K=0.18) Oil (K=0.15) Moly (K=0.12) Clamp (kN) Proof (kN)
Grade 5 CURRENT 872.677 Nm
643.653 ft-lb
785.409 Nm
579.288 ft-lb
654.508 Nm
482.74 ft-lb
523.606 Nm
386.192 ft-lb
171.787 229.049
Grade 8 1231.962 Nm
908.648 ft-lb
1108.766 Nm
817.784 ft-lb
923.971 Nm
681.486 ft-lb
739.177 Nm
545.189 ft-lb
242.512 323.35
18-8 Stainless 462.023 Nm
340.771 ft-lb
415.821 Nm
306.694 ft-lb
346.517 Nm
255.578 ft-lb
277.214 Nm
204.462 ft-lb
90.949 121.266

Frequently Asked Engineering Questions (1"-8 UNC Grade 5)

What is the recommended tightening torque for a 1"-8 UNC Grade 5 bolt?
For a 1"-8 UNC SAE J429 Grade 5 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 872.677 N·m (643.653 ft-lbs / 7723.84 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 654.508 N·m (482.74 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 523.606 N·m (386.192 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping 1"-8 UNC internal threads?
The standard cut tap drill size for 1"-8 UNC is 7/8" (0.8750 in) (0.8750" / 22.225 mm), which delivers approximately 92.4% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 23.68 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a 1"-8 UNC Grade 5 fastener develop?
With a tensile stress area (As) of 390.802 mm² (0.60574 in²) and a nominal proof stress of 586.1 MPa (85,000 psi), a 1"-8 UNC Grade 5 fastener possesses an ultimate proof load of 229.049 kN (51,492.3 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 171.787 kN (38,619.2 lbf) across the joint interface.
What clearance hole diameters should be drilled for 1"-8 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a 1"-8 UNC fastener are: Close Fit = 25.806 mm (1.016"), Normal Fit = 26.187 mm (1.031"), and Loose Fit = 27 mm (1.063"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.