5/16"-18 UNC 18-8 Stainless Torque & Tap Drill Spec
ASTM F593 Group 1 / AISI 304Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
12.497 N·m
9.217 ft-lbs | 110.61 in-lbs | 1.2743 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
7.872 kN
1,769.7 lbf
Target tension across joint interface
75% Tap Drill d - P
6.528 mm
F (0.2570 in) (92.3% Eng.)
50% Hard Metal Drill: 7.173 mm
Direct Engineering Specification Summary
The recommended tightening torque for a 5/16"-18 UNC 18-8 Stainless bolt is 12.497 N·m (9.217 ft-lbs) when dry (K=0.20) and 9.373 N·m (6.913 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 7.872 kN (1,769.7 lbf) at 75% proof load. Standard 75% tap drill is F (0.2570 in).
Thread & Hole Blueprint Visualizer
ASME B1.1 Unified Inch Screw Threads (60° UN) Stress Area (As) 33.826 mm²
Pitch Diameter (d2) 7.021 mm
Minor Diameter (d1) 6.41 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (7.9375 − 0.9382 × 1.41111)² = 33.826 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 33.826 mm² × 310.3 N/mm² = 10496 N (10.496 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 10496 N = 7872 N (7.872 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 7.9375 mm × 7872 N) / 1000 = 12.497 N·m (9.217 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
5/16"-18 UNC Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Grade 5 | 23.605 Nm 17.41 ft-lb | 21.244 Nm 15.669 ft-lb | 17.703 Nm 13.057 ft-lb | 14.163 Nm 10.446 ft-lb | 14.869 | 19.825 |
| Grade 8 | 33.323 Nm 24.578 ft-lb | 29.99 Nm 22.12 ft-lb | 24.992 Nm 18.433 ft-lb | 19.994 Nm 14.747 ft-lb | 20.991 | 27.988 |
| 18-8 Stainless CURRENT | 12.497 Nm 9.217 ft-lb | 11.247 Nm 8.296 ft-lb | 9.373 Nm 6.913 ft-lb | 7.498 Nm 5.53 ft-lb | 7.872 | 10.496 |
Frequently Asked Engineering Questions (5/16"-18 UNC 18-8 Stainless)
What is the recommended tightening torque for a 5/16"-18 UNC 18-8 Stainless bolt?
For a 5/16"-18 UNC 18-8 Stainless Steel (ASTM F593 Group 1) bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 12.497 N·m (9.217 ft-lbs / 110.61 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 9.373 N·m (6.913 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 7.498 N·m (5.53 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping 5/16"-18 UNC internal threads?
The standard cut tap drill size for 5/16"-18 UNC is F (0.2570 in) (0.2570" / 6.528 mm), which delivers approximately 92.3% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 7.173 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a 5/16"-18 UNC 18-8 Stainless fastener develop?
With a tensile stress area (As) of 33.826 mm² (0.05243 in²) and a nominal proof stress of 310.3 MPa (45,000 psi), a 5/16"-18 UNC 18-8 Stainless fastener possesses an ultimate proof load of 10.496 kN (2,359.6 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 7.872 kN (1,769.7 lbf) across the joint interface.
What clearance hole diameters should be drilled for 5/16"-18 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a 5/16"-18 UNC fastener are: Close Fit = 8.204 mm (0.323"), Normal Fit = 8.433 mm (0.332"), and Loose Fit = 8.738 mm (0.344"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations
No recent calculations saved yet.