Skip to calculator
⚙️
TorqueAndFeed TorqueAndFeed.com • B2B Reference

5/8"-11 UNC Grade 5 Torque & Tap Drill Spec

SAE J429 / ASTM A449

Live Joint Clamp & Torque Engine

K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
203.496 N·m
150.091 ft-lbs | 1801.09 in-lbs | 20.7508 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
64.093 kN
14,408.7 lbf
Target tension across joint interface
75% Tap Drill d - P
13.492 mm
17/32" (0.5312 in) (95.3% Eng.)
50% Hard Metal Drill: 14.625 mm
Direct Engineering Specification Summary

The recommended tightening torque for a 5/8"-11 UNC Grade 5 bolt is 203.496 N·m (150.091 ft-lbs) when dry (K=0.20) and 152.622 N·m (112.568 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 64.093 kN (14,408.7 lbf) at 75% proof load. Standard 75% tap drill is 17/32" (0.5312 in).

Thread & Hole Blueprint Visualizer

ASME B1.1 Unified Inch Screw Threads (60° UN)
d = 15.875 mm (0.625") P = 2.30909 mm 5/8"-11 UNC Close: 16.281mm Normal: 16.662mm Loose: 17.475mm
Stress Area (As) 145.807 mm²
Pitch Diameter (d2) 14.375 mm
Minor Diameter (d1) 13.375 mm

Step-by-Step Mathematical Derivation

VDI 2230 / ISO 898-1
Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (15.875 − 0.9382 × 2.30909)² = 145.807 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 145.807 mm² × 586.1 N/mm² = 85457 N (85.457 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 85457 N = 64093 N (64.093 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 15.875 mm × 64093 N) / 1000 = 203.496 N·m (150.091 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.

5/8"-11 UNC Torque Across All Grades & Friction Conditions

Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.

Nominal Size: 5/8"-11 UNC
Grade / Class Dry (K=0.20) Zinc (K=0.18) Oil (K=0.15) Moly (K=0.12) Clamp (kN) Proof (kN)
Grade 5 CURRENT 203.496 Nm
150.091 ft-lb
183.146 Nm
135.082 ft-lb
152.622 Nm
112.568 ft-lb
122.097 Nm
90.054 ft-lb
64.093 85.457
Grade 8 287.276 Nm
211.884 ft-lb
258.548 Nm
190.695 ft-lb
215.457 Nm
158.913 ft-lb
172.365 Nm
127.13 ft-lb
90.481 120.641
18-8 Stainless 107.737 Nm
79.463 ft-lb
96.963 Nm
71.517 ft-lb
80.803 Nm
59.597 ft-lb
64.642 Nm
47.678 ft-lb
33.933 45.244

Frequently Asked Engineering Questions (5/8"-11 UNC Grade 5)

What is the recommended tightening torque for a 5/8"-11 UNC Grade 5 bolt?
For a 5/8"-11 UNC SAE J429 Grade 5 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 203.496 N·m (150.091 ft-lbs / 1801.09 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 152.622 N·m (112.568 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 122.097 N·m (90.054 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping 5/8"-11 UNC internal threads?
The standard cut tap drill size for 5/8"-11 UNC is 17/32" (0.5312 in) (0.5312" / 13.492 mm), which delivers approximately 95.3% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 14.625 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a 5/8"-11 UNC Grade 5 fastener develop?
With a tensile stress area (As) of 145.807 mm² (0.226 in²) and a nominal proof stress of 586.1 MPa (85,000 psi), a 5/8"-11 UNC Grade 5 fastener possesses an ultimate proof load of 85.457 kN (19,211.6 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 64.093 kN (14,408.7 lbf) across the joint interface.
What clearance hole diameters should be drilled for 5/8"-11 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a 5/8"-11 UNC fastener are: Close Fit = 16.281 mm (0.641"), Normal Fit = 16.662 mm (0.656"), and Loose Fit = 17.475 mm (0.688"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.