M6 x 1.0 A2-70 Stainless Torque & Tap Drill Spec
ISO 3506-1Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
8.15 N·m
6.011 ft-lbs | 72.13 in-lbs | 0.831 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
6.792 kN
1,526.8 lbf
Target tension across joint interface
75% Tap Drill d - P
5 mm
5.0 mm (92.4% Eng.)
50% Hard Metal Drill: 5.459 mm
Direct Engineering Specification Summary
The recommended tightening torque for a M6 x 1.0 A2-70 Stainless bolt is 8.15 N·m (6.011 ft-lbs) when dry (K=0.20) and 6.112 N·m (4.508 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 6.792 kN (1,526.8 lbf) at 75% proof load. Standard 75% tap drill is 5.0 mm.
Thread & Hole Blueprint Visualizer
ISO 261 / ISO 965-1 (Metric 60°) Stress Area (As) 20.123 mm²
Pitch Diameter (d2) 5.35 mm
Minor Diameter (d1) 4.917 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (6 − 0.9382 × 1)² = 20.123 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 20.123 mm² × 450 N/mm² = 9055 N (9.055 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 9055 N = 6792 N (6.792 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 6 mm × 6792 N) / 1000 = 8.15 N·m (6.011 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
M6 x 1.0 Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Class 8.8 | 10.866 Nm 8.015 ft-lb | 9.78 Nm 7.213 ft-lb | 8.15 Nm 6.011 ft-lb | 6.52 Nm 4.809 ft-lb | 9.055 | 12.074 |
| Class 10.9 | 15.032 Nm 11.087 ft-lb | 13.529 Nm 9.978 ft-lb | 11.274 Nm 8.315 ft-lb | 9.019 Nm 6.652 ft-lb | 12.527 | 16.702 |
| Class 12.9 | 17.567 Nm 12.957 ft-lb | 15.811 Nm 11.661 ft-lb | 13.176 Nm 9.718 ft-lb | 10.54 Nm 7.774 ft-lb | 14.639 | 19.519 |
| A2-70 Stainless CURRENT | 8.15 Nm 6.011 ft-lb | 7.335 Nm 5.41 ft-lb | 6.112 Nm 4.508 ft-lb | 4.89 Nm 3.607 ft-lb | 6.792 | 9.055 |
| A4-80 Marine Stainless | 10.866 Nm 8.015 ft-lb | 9.78 Nm 7.213 ft-lb | 8.15 Nm 6.011 ft-lb | 6.52 Nm 4.809 ft-lb | 9.055 | 12.074 |
Frequently Asked Engineering Questions (M6 x 1.0 A2-70 Stainless)
What is the recommended tightening torque for a M6 x 1.0 A2-70 Stainless bolt?
For a M6 x 1.0 Stainless Steel A2-70 (AISI 304 / EN 1.4301) bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 8.15 N·m (6.011 ft-lbs / 72.13 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 6.112 N·m (4.508 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 4.89 N·m (3.607 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping M6 x 1.0 internal threads?
The standard cut tap drill size for M6 x 1.0 is 5.0 mm (0.1969" / 5 mm), which delivers approximately 92.4% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 5.459 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a M6 x 1.0 A2-70 Stainless fastener develop?
With a tensile stress area (As) of 20.123 mm² (0.03119 in²) and a nominal proof stress of 450 MPa (65,267 psi), a M6 x 1.0 A2-70 Stainless fastener possesses an ultimate proof load of 9.055 kN (2,035.7 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 6.792 kN (1,526.8 lbf) across the joint interface.
What clearance hole diameters should be drilled for M6 x 1.0 bolts?
Per ISO 273 (Bolts & Screws Clearance Holes), recommended clearance hole diameters for a M6 x 1.0 fastener are: Close Fit = 6.4 mm (0.252"), Normal Fit = 6.6 mm (0.2598"), and Loose Fit = 7 mm (0.2756"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations
No recent calculations saved yet.