Skip to calculator
⚙️
TorqueAndFeed TorqueAndFeed.com • B2B Reference

M8 x 1.25 Class 10.9 Torque & Tap Drill Spec

ISO 898-1

Live Joint Clamp & Torque Engine

K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
36.462 N·m
26.893 ft-lbs | 322.71 in-lbs | 3.718 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
22.788 kN
5,123.1 lbf
Target tension across joint interface
75% Tap Drill d - P
6.8 mm
6.8 mm (88.7% Eng.)
50% Hard Metal Drill: 7.323 mm
Direct Engineering Specification Summary

The recommended tightening torque for a M8 x 1.25 Class 10.9 bolt is 36.462 N·m (26.893 ft-lbs) when dry (K=0.20) and 27.346 N·m (20.17 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 22.788 kN (5,123.1 lbf) at 75% proof load. Standard 75% tap drill is 6.8 mm.

Thread & Hole Blueprint Visualizer

ISO 261 / ISO 965-1 (Metric 60°)
d = 8 mm (0.315") P = 1.25 mm M8 x 1.25 Close: 8.4mm Normal: 9mm Loose: 10mm
Stress Area (As) 36.608 mm²
Pitch Diameter (d2) 7.188 mm
Minor Diameter (d1) 6.647 mm

Step-by-Step Mathematical Derivation

VDI 2230 / ISO 898-1
Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (8 − 0.9382 × 1.25)² = 36.608 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 36.608 mm² × 830 N/mm² = 30385 N (30.385 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 30385 N = 22788 N (22.788 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 8 mm × 22788 N) / 1000 = 36.462 N·m (26.893 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.

M8 x 1.25 Torque Across All Grades & Friction Conditions

Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.

Nominal Size: M8 x 1.25
Grade / Class Dry (K=0.20) Zinc (K=0.18) Oil (K=0.15) Moly (K=0.12) Clamp (kN) Proof (kN)
Class 8.8 26.358 Nm
19.44 ft-lb
23.722 Nm
17.496 ft-lb
19.768 Nm
14.58 ft-lb
15.815 Nm
11.664 ft-lb
16.474 21.965
Class 10.9 CURRENT 36.462 Nm
26.893 ft-lb
32.815 Nm
24.203 ft-lb
27.346 Nm
20.17 ft-lb
21.877 Nm
16.136 ft-lb
22.788 30.385
Class 12.9 42.612 Nm
31.429 ft-lb
38.351 Nm
28.286 ft-lb
31.959 Nm
23.572 ft-lb
25.567 Nm
18.857 ft-lb
26.632 35.51
A2-70 Stainless 19.768 Nm
14.58 ft-lb
17.791 Nm
13.122 ft-lb
14.826 Nm
10.935 ft-lb
11.861 Nm
8.748 ft-lb
12.355 16.474
A4-80 Marine Stainless 26.358 Nm
19.44 ft-lb
23.722 Nm
17.496 ft-lb
19.768 Nm
14.58 ft-lb
15.815 Nm
11.664 ft-lb
16.474 21.965

Frequently Asked Engineering Questions (M8 x 1.25 Class 10.9)

What is the recommended tightening torque for a M8 x 1.25 Class 10.9 bolt?
For a M8 x 1.25 ISO Metric Property Class 10.9 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 36.462 N·m (26.893 ft-lbs / 322.71 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 27.346 N·m (20.17 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 21.877 N·m (16.136 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping M8 x 1.25 internal threads?
The standard cut tap drill size for M8 x 1.25 is 6.8 mm (0.2677" / 6.8 mm), which delivers approximately 88.7% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 7.323 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a M8 x 1.25 Class 10.9 fastener develop?
With a tensile stress area (As) of 36.608 mm² (0.05674 in²) and a nominal proof stress of 830 MPa (1,20,381 psi), a M8 x 1.25 Class 10.9 fastener possesses an ultimate proof load of 30.385 kN (6,830.7 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 22.788 kN (5,123.1 lbf) across the joint interface.
What clearance hole diameters should be drilled for M8 x 1.25 bolts?
Per ISO 273 (Bolts & Screws Clearance Holes), recommended clearance hole diameters for a M8 x 1.25 fastener are: Close Fit = 8.4 mm (0.3307"), Normal Fit = 9 mm (0.3543"), and Loose Fit = 10 mm (0.3937"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.