1/4"-20 UNC 18-8 Stainless Torque & Tap Drill Spec
ASTM F593 Group 1 / AISI 304Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
6.068 N·m
4.475 ft-lbs | 53.71 in-lbs | 0.6187 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
4.778 kN
1,074.1 lbf
Target tension across joint interface
75% Tap Drill d - P
5.105 mm
#7 (0.2010 in) (90.5% Eng.)
50% Hard Metal Drill: 5.662 mm
Direct Engineering Specification Summary
The recommended tightening torque for a 1/4"-20 UNC 18-8 Stainless bolt is 6.068 N·m (4.475 ft-lbs) when dry (K=0.20) and 4.551 N·m (3.357 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 4.778 kN (1,074.1 lbf) at 75% proof load. Standard 75% tap drill is #7 (0.2010 in).
Thread & Hole Blueprint Visualizer
ASME B1.1 Unified Inch Screw Threads (60° UN) Stress Area (As) 20.53 mm²
Pitch Diameter (d2) 5.525 mm
Minor Diameter (d1) 4.975 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (6.35 − 0.9382 × 1.27)² = 20.53 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 20.53 mm² × 310.3 N/mm² = 6370 N (6.37 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 6370 N = 4778 N (4.778 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 6.35 mm × 4778 N) / 1000 = 6.068 N·m (4.475 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
1/4"-20 UNC Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Grade 5 | 11.461 Nm 8.453 ft-lb | 10.315 Nm 7.608 ft-lb | 8.596 Nm 6.34 ft-lb | 6.877 Nm 5.072 ft-lb | 9.024 | 12.033 |
| Grade 8 | 16.18 Nm 11.934 ft-lb | 14.562 Nm 10.74 ft-lb | 12.135 Nm 8.95 ft-lb | 9.708 Nm 7.16 ft-lb | 12.74 | 16.987 |
| 18-8 Stainless CURRENT | 6.068 Nm 4.475 ft-lb | 5.461 Nm 4.028 ft-lb | 4.551 Nm 3.357 ft-lb | 3.641 Nm 2.685 ft-lb | 4.778 | 6.37 |
Frequently Asked Engineering Questions (1/4"-20 UNC 18-8 Stainless)
What is the recommended tightening torque for a 1/4"-20 UNC 18-8 Stainless bolt?
For a 1/4"-20 UNC 18-8 Stainless Steel (ASTM F593 Group 1) bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 6.068 N·m (4.475 ft-lbs / 53.71 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 4.551 N·m (3.357 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 3.641 N·m (2.685 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping 1/4"-20 UNC internal threads?
The standard cut tap drill size for 1/4"-20 UNC is #7 (0.2010 in) (0.2010" / 5.105 mm), which delivers approximately 90.5% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 5.662 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a 1/4"-20 UNC 18-8 Stainless fastener develop?
With a tensile stress area (As) of 20.53 mm² (0.03182 in²) and a nominal proof stress of 310.3 MPa (45,000 psi), a 1/4"-20 UNC 18-8 Stainless fastener possesses an ultimate proof load of 6.37 kN (1,432.1 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 4.778 kN (1,074.1 lbf) across the joint interface.
What clearance hole diameters should be drilled for 1/4"-20 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a 1/4"-20 UNC fastener are: Close Fit = 6.528 mm (0.257"), Normal Fit = 6.756 mm (0.266"), and Loose Fit = 7.137 mm (0.281"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations
No recent calculations saved yet.