#10-32 UNF 18-8 Stainless Torque & Tap Drill Spec
ASTM F593 Group 1 / AISI 304Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
2.897 N·m
2.137 ft-lbs | 25.64 in-lbs | 0.2955 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
3.002 kN
674.9 lbf
Target tension across joint interface
75% Tap Drill d - P
4.039 mm
#21 (0.1590 in) (91.6% Eng.)
50% Hard Metal Drill: 4.397 mm
Direct Engineering Specification Summary
The recommended tightening torque for a #10-32 UNF 18-8 Stainless bolt is 2.897 N·m (2.137 ft-lbs) when dry (K=0.20) and 2.173 N·m (1.603 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 3.002 kN (674.9 lbf) at 75% proof load. Standard 75% tap drill is #21 (0.1590 in).
Thread & Hole Blueprint Visualizer
ASME B1.1 Unified Inch Screw Threads (60° UN) Stress Area (As) 12.899 mm²
Pitch Diameter (d2) 4.31 mm
Minor Diameter (d1) 3.967 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (4.826 − 0.9382 × 0.79375)² = 12.899 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 12.899 mm² × 310.3 N/mm² = 4003 N (4.003 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 4003 N = 3002 N (3.002 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 4.826 mm × 3002 N) / 1000 = 2.897 N·m (2.137 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
#10-32 UNF Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Grade 5 | 5.473 Nm 4.037 ft-lb | 4.925 Nm 3.633 ft-lb | 4.105 Nm 3.027 ft-lb | 3.284 Nm 2.422 ft-lb | 5.67 | 7.56 |
| Grade 8 | 7.726 Nm 5.698 ft-lb | 6.953 Nm 5.129 ft-lb | 5.794 Nm 4.274 ft-lb | 4.636 Nm 3.419 ft-lb | 8.004 | 10.673 |
| 18-8 Stainless CURRENT | 2.897 Nm 2.137 ft-lb | 2.608 Nm 1.923 ft-lb | 2.173 Nm 1.603 ft-lb | 1.738 Nm 1.282 ft-lb | 3.002 | 4.003 |
Frequently Asked Engineering Questions (#10-32 UNF 18-8 Stainless)
What is the recommended tightening torque for a #10-32 UNF 18-8 Stainless bolt?
For a #10-32 UNF 18-8 Stainless Steel (ASTM F593 Group 1) bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 2.897 N·m (2.137 ft-lbs / 25.64 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 2.173 N·m (1.603 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 1.738 N·m (1.282 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping #10-32 UNF internal threads?
The standard cut tap drill size for #10-32 UNF is #21 (0.1590 in) (0.1590" / 4.039 mm), which delivers approximately 91.6% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 4.397 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a #10-32 UNF 18-8 Stainless fastener develop?
With a tensile stress area (As) of 12.899 mm² (0.01999 in²) and a nominal proof stress of 310.3 MPa (45,000 psi), a #10-32 UNF 18-8 Stainless fastener possesses an ultimate proof load of 4.003 kN (899.8 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 3.002 kN (674.9 lbf) across the joint interface.
What clearance hole diameters should be drilled for #10-32 UNF bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a #10-32 UNF fastener are: Close Fit = 5.182 mm (0.204"), Normal Fit = 5.613 mm (0.221"), and Loose Fit = 5.944 mm (0.234"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations
No recent calculations saved yet.