#10-24 UNC Grade 8 Torque & Tap Drill Spec
SAE J429 / ASTM A354 Grade BDLive Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
6.775 N·m
4.997 ft-lbs | 59.96 in-lbs | 0.6908 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
7.019 kN
1,577.9 lbf
Target tension across joint interface
75% Tap Drill d - P
3.797 mm
#25 (0.1495 in) (89.8% Eng.)
50% Hard Metal Drill: 4.252 mm
Direct Engineering Specification Summary
The recommended tightening torque for a #10-24 UNC Grade 8 bolt is 6.775 N·m (4.997 ft-lbs) when dry (K=0.20) and 5.081 N·m (3.748 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 7.019 kN (1,577.9 lbf) at 75% proof load. Standard 75% tap drill is #25 (0.1495 in).
Thread & Hole Blueprint Visualizer
ASME B1.1 Unified Inch Screw Threads (60° UN) Stress Area (As) 11.311 mm²
Pitch Diameter (d2) 4.139 mm
Minor Diameter (d1) 3.68 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (4.826 − 0.9382 × 1.05833)² = 11.311 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 11.311 mm² × 827.4 N/mm² = 9359 N (9.359 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 9359 N = 7019 N (7.019 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 4.826 mm × 7019 N) / 1000 = 6.775 N·m (4.997 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
#10-24 UNC Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Grade 5 | 4.799 Nm 3.54 ft-lb | 4.319 Nm 3.186 ft-lb | 3.599 Nm 2.655 ft-lb | 2.879 Nm 2.124 ft-lb | 4.972 | 6.629 |
| Grade 8 CURRENT | 6.775 Nm 4.997 ft-lb | 6.097 Nm 4.497 ft-lb | 5.081 Nm 3.748 ft-lb | 4.065 Nm 2.998 ft-lb | 7.019 | 9.359 |
| 18-8 Stainless | 2.541 Nm 1.874 ft-lb | 2.287 Nm 1.687 ft-lb | 1.906 Nm 1.405 ft-lb | 1.524 Nm 1.124 ft-lb | 2.632 | 3.51 |
Frequently Asked Engineering Questions (#10-24 UNC Grade 8)
What is the recommended tightening torque for a #10-24 UNC Grade 8 bolt?
For a #10-24 UNC SAE J429 Grade 8 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 6.775 N·m (4.997 ft-lbs / 59.96 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 5.081 N·m (3.748 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 4.065 N·m (2.998 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping #10-24 UNC internal threads?
The standard cut tap drill size for #10-24 UNC is #25 (0.1495 in) (0.1495" / 3.797 mm), which delivers approximately 89.8% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 4.252 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a #10-24 UNC Grade 8 fastener develop?
With a tensile stress area (As) of 11.311 mm² (0.01753 in²) and a nominal proof stress of 827.4 MPa (1,20,000 psi), a #10-24 UNC Grade 8 fastener possesses an ultimate proof load of 9.359 kN (2,103.9 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 7.019 kN (1,577.9 lbf) across the joint interface.
What clearance hole diameters should be drilled for #10-24 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a #10-24 UNC fastener are: Close Fit = 5.182 mm (0.204"), Normal Fit = 5.613 mm (0.221"), and Loose Fit = 5.944 mm (0.234"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations