#8-32 UNC 18-8 Stainless Torque & Tap Drill Spec
ASTM F593 Group 1 / AISI 304Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
1.752 N·m
1.292 ft-lbs | 15.51 in-lbs | 0.1787 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
2.103 kN
472.9 lbf
Target tension across joint interface
75% Tap Drill d - P
3.454 mm
#29 (0.1360 in) (82.8% Eng.)
50% Hard Metal Drill: 3.736 mm
Direct Engineering Specification Summary
The recommended tightening torque for a #8-32 UNC 18-8 Stainless bolt is 1.752 N·m (1.292 ft-lbs) when dry (K=0.20) and 1.314 N·m (0.969 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 2.103 kN (472.9 lbf) at 75% proof load. Standard 75% tap drill is #29 (0.1360 in).
Thread & Hole Blueprint Visualizer
ASME B1.1 Unified Inch Screw Threads (60° UN) Stress Area (As) 9.038 mm²
Pitch Diameter (d2) 3.65 mm
Minor Diameter (d1) 3.306 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (4.1656 − 0.9382 × 0.79375)² = 9.038 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 9.038 mm² × 310.3 N/mm² = 2804 N (2.804 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 2804 N = 2103 N (2.103 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 4.1656 mm × 2103 N) / 1000 = 1.752 N·m (1.292 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
#8-32 UNC Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Grade 5 | 3.31 Nm 2.441 ft-lb | 2.979 Nm 2.197 ft-lb | 2.482 Nm 1.831 ft-lb | 1.986 Nm 1.465 ft-lb | 3.973 | 5.297 |
| Grade 8 | 4.673 Nm 3.446 ft-lb | 4.205 Nm 3.102 ft-lb | 3.504 Nm 2.585 ft-lb | 2.804 Nm 2.068 ft-lb | 5.609 | 7.478 |
| 18-8 Stainless CURRENT | 1.752 Nm 1.292 ft-lb | 1.577 Nm 1.163 ft-lb | 1.314 Nm 0.969 ft-lb | 1.051 Nm 0.775 ft-lb | 2.103 | 2.804 |
Frequently Asked Engineering Questions (#8-32 UNC 18-8 Stainless)
What is the recommended tightening torque for a #8-32 UNC 18-8 Stainless bolt?
For a #8-32 UNC 18-8 Stainless Steel (ASTM F593 Group 1) bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 1.752 N·m (1.292 ft-lbs / 15.51 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 1.314 N·m (0.969 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 1.051 N·m (0.775 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping #8-32 UNC internal threads?
The standard cut tap drill size for #8-32 UNC is #29 (0.1360 in) (0.1360" / 3.454 mm), which delivers approximately 82.8% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 3.736 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a #8-32 UNC 18-8 Stainless fastener develop?
With a tensile stress area (As) of 9.038 mm² (0.01401 in²) and a nominal proof stress of 310.3 MPa (45,000 psi), a #8-32 UNC 18-8 Stainless fastener possesses an ultimate proof load of 2.804 kN (630.5 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 2.103 kN (472.9 lbf) across the joint interface.
What clearance hole diameters should be drilled for #8-32 UNC bolts?
Per ASME B18.2.8 (Clearance Holes for Bolts, Screws, and Studs), recommended clearance hole diameters for a #8-32 UNC fastener are: Close Fit = 4.496 mm (0.177"), Normal Fit = 4.978 mm (0.196"), and Loose Fit = 5.309 mm (0.209"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations