M5 x 0.8 Class 12.9 Torque & Tap Drill Spec
ISO 898-1Live Joint Clamp & Torque Engine
K = 0.20
75% Sp
Lubrication Condition Presets:
Recommended Tightening Torque T = K·d·Fi
10.318 N·m
7.61 ft-lbs | 91.32 in-lbs | 1.0522 kgf·m
Calibrated for Dry / Bare Steel conditions.
Clamp Preload Fi
10.318 kN
2,319.6 lbf
Target tension across joint interface
75% Tap Drill d - P
4.2 mm
4.2 mm (92.4% Eng.)
50% Hard Metal Drill: 4.567 mm
Direct Engineering Specification Summary
The recommended tightening torque for a M5 x 0.8 Class 12.9 bolt is 10.318 N·m (7.61 ft-lbs) when dry (K=0.20) and 7.739 N·m (5.708 ft-lbs) when lubricated (K=0.15), generating a clamp preload of 10.318 kN (2,319.6 lbf) at 75% proof load. Standard 75% tap drill is 4.2 mm.
Thread & Hole Blueprint Visualizer
ISO 261 / ISO 965-1 (Metric 60°) Stress Area (As) 14.183 mm²
Pitch Diameter (d2) 4.48 mm
Minor Diameter (d1) 4.134 mm
Step-by-Step Mathematical Derivation
VDI 2230 / ISO 898-1Step 1: Tensile Stress Area (As)
As = (π / 4) × (d − 0.9382 × P)²
As = (π / 4) × (5 − 0.9382 × 0.8)² = 14.183 mm²
Step 2: Proof Load (Fp)
Fp = As × Sp
Fp = 14.183 mm² × 970 N/mm² = 13758 N (13.758 kN)
Step 3: Target Clamp Preload (Fi @ 75% Proof)
Fi = 0.75 × Fp
Fi = 0.75 × 13758 N = 10318 N (10.318 kN)
Step 4: Tightening Torque (Dry K=0.20)
T = (K × d × Fi) / 1000
T = (0.20 × 5 mm × 10318 N) / 1000 = 10.318 N·m (7.61 ft-lbs)
Formula verified per ISO 898-1 and Machinery's Handbook 31st Edition. Assumes unhardened flat washer under head.
M5 x 0.8 Torque Across All Grades & Friction Conditions
Comparison matrix calculated at 75% proof stress preload across Dry, Zinc, Oil, and Anti-Seize.
| Grade / Class | Dry (K=0.20) | Zinc (K=0.18) | Oil (K=0.15) | Moly (K=0.12) | Clamp (kN) | Proof (kN) |
|---|---|---|---|---|---|---|
| Class 8.8 | 6.382 Nm 4.707 ft-lb | 5.744 Nm 4.237 ft-lb | 4.787 Nm 3.531 ft-lb | 3.829 Nm 2.824 ft-lb | 6.382 | 8.51 |
| Class 10.9 | 8.829 Nm 6.512 ft-lb | 7.946 Nm 5.861 ft-lb | 6.622 Nm 4.884 ft-lb | 5.297 Nm 3.907 ft-lb | 8.829 | 11.772 |
| Class 12.9 CURRENT | 10.318 Nm 7.61 ft-lb | 9.286 Nm 6.849 ft-lb | 7.739 Nm 5.708 ft-lb | 6.191 Nm 4.566 ft-lb | 10.318 | 13.758 |
| A2-70 Stainless | 4.787 Nm 3.531 ft-lb | 4.308 Nm 3.177 ft-lb | 3.59 Nm 2.648 ft-lb | 2.872 Nm 2.118 ft-lb | 4.787 | 6.382 |
| A4-80 Marine Stainless | 6.382 Nm 4.707 ft-lb | 5.744 Nm 4.237 ft-lb | 4.787 Nm 3.531 ft-lb | 3.829 Nm 2.824 ft-lb | 6.382 | 8.51 |
Frequently Asked Engineering Questions (M5 x 0.8 Class 12.9)
What is the recommended tightening torque for a M5 x 0.8 Class 12.9 bolt?
For a M5 x 0.8 ISO Metric Property Class 12.9 bolt torqued to 75% of proof load, the standard dry (unplated, K=0.20) tightening torque is 10.318 N·m (7.61 ft-lbs / 91.32 in-lbs). If lubricated with light machine oil (K=0.15), torque must be reduced to 7.739 N·m (5.708 ft-lbs). Under anti-seize paste (K=0.12), the recommended torque is 6.191 N·m (4.566 ft-lbs). Failure to reduce torque when lubricating causes bolt over-stretching or thread stripping.
What tap drill size should be used for tapping M5 x 0.8 internal threads?
The standard cut tap drill size for M5 x 0.8 is 4.2 mm (0.1654" / 4.2 mm), which delivers approximately 92.4% theoretical thread engagement. For extremely tough parent alloys (e.g. titanium, 17-4 PH stainless, Inconel), a 50% engagement drill of 4.567 mm is recommended to prevent tap binding and breakage without compromising joint pull-out strength.
What clamp preload and proof load does a M5 x 0.8 Class 12.9 fastener develop?
With a tensile stress area (As) of 14.183 mm² (0.02198 in²) and a nominal proof stress of 970 MPa (1,40,687 psi), a M5 x 0.8 Class 12.9 fastener possesses an ultimate proof load of 13.758 kN (3,092.8 lbf). At the standard 75% proof preload threshold, the fastener exerts a clamping force of 10.318 kN (2,319.6 lbf) across the joint interface.
What clearance hole diameters should be drilled for M5 x 0.8 bolts?
Per ISO 273 (Bolts & Screws Clearance Holes), recommended clearance hole diameters for a M5 x 0.8 fastener are: Close Fit = 5.3 mm (0.2087"), Normal Fit = 5.5 mm (0.2165"), and Loose Fit = 5.8 mm (0.2283"). Normal fit is standard for general machinery assemblies, while Close fit is reserved for high-precision dowel-aligned flanges.
Recent Calculations
No recent calculations saved yet.